FABRILINE BEAMLINE HYDRAULIC POWER UNIT

TYPICAL FABRILINE HYDRAULIC POWER UNIT

 

1.) ARE ANY OUT-FEED DUMPS, TRANSFER CONVEYORS, ETC. POWERED FROM THE BEAMLINE H.P.U.? IF SO, DESCRIBE OPERATIONS OF TRANSFERS, PRESSURES THEY OPERATE AT, AND IF VALVES ARE MOUNTED ON H.P.U. OR REMOTELY.

 

 

 

 

 

 

2.) WHAT IS MAIN ELECTRIC SUPPLY VOLTAGE: 230V, 460V, 575V? (CHECK VOLTAGE COMING INTO MACHINE.)

 

 

3.) HAS A NEW OR REBUILT HYDRAULIC POWER UNIT BEEN PURCHASED TO GO WITH YOUR RETROFIT? IF SO, DISREGARD THE REST OF THE QUESTIONS IN THIS SECTION.

 

 

4.) DOES THE UNIT HAVE AN OIL COOLER? IF SO, GET ALL NAMEPLATE DATA FROM THE COOLER AND ITS FAN MOTOR.

RETROFIT HYDRAULIC POWER UNIT WITH OIL COOLER MOUNTED ON RIGHT SIDE

 

 

 

 

 

 

5.) GET ALL NAMEPLATE DATA FROM BOTH PUMPS AND THE ELECTRIC MOTOR. (MAKE SURE TO LIST MANUFACTURER.)

 

 

 

 

 

 

 

 

 

 

 

6.) HOW FAR IS THE H.P.U. MOUNTED FROM THE BACK OF THE WEB PUNCH FRAME? WE NEED TO KNOW THESE DIMENSIONS IN ORDER TO REINSTALL WITH PROPER HOSE LENGTHS.

7.) DOES THE UNIT HAVE AN OIL HEATER? (TO DETERMINE, LOOK FOR HEATING ELEMENT AND THERMOSTAT)

 

 

8.)CONDITION OF HOSES:

  1. ARE THERE ANY LEAKS?

  2. IS THE UNDERLYING METAL SHOWING ANYWHERE ON THE HOSES?

     
     

  3. OVERALL CONDITION OF HOSES?

    GOOD
     
    FAIR
     
    BAD
     

 

9.) WHAT IS THE CONDITION OF THE H.P.U. ELECTRIC MOTOR ?

LIST ANY OTHER OBSERVATIONS THAT MAY BE HELPFUL.

 

 

10.) ARE THERE ANY LEAKS IN THE H.P.U VALVES? IF SO, VALVES WILL NEED TO BE REPLACED.

 

 

11.) DOES UNIT BUILD 2,500 PSI FOR PUNCHING WHEN HIGH PRESSURE VALVE IS OPERATED? IF NOT, THIS MAY INDICATE A BAD COMPONENT OR COMPONENTS ON THE H.P.U.

 

 

12.) HYDRAULIC OIL CONDITION: DIRTY OIL CAN CAUSE THE PUMP OR OTHER H.P.U. COMPONENTS TO GO BAD.

  1. CAN DIRT OR METAL FRAGMENTS BE FOUND IN THE OIL?

  2. WHAT IS THE COLOR OF THE OIL?

  3. OVERALL HYDRAULIC OIL CONDITION?

    GOOD
     
    FAIR
     
    BAD
     

WHAT IS THE CONDITION OF THE HYDRAULIC PUMP? ( POOR PRESSURE BUILD MAY INDICATE A BAD PUMP)

13.) IF POSSIBLE, SEND A COPY OF THE ORIGINAL FABRILINE HYDRAULIC SCHEMATIC TO CONTROLLED AUTOMATION.

14.) ARE REPLACEMENT DUAL SOLENOID PUNCH VALVES BEING PURCHASED WITH RETROFIT? (THE DUAL SOLENOID VALVES KEEP UNNECESSARY PRESSURE FROM PUNCH CYLINDERS WHICH GREATLY DECREASES SERVICE PROBLEMS WITH THE PUNCH CYLINDERS)

 