Controlled Automation Inc.
Controlled Automation Cad Conversion Format
The Cad Conversion is an option with the Controlled Automation software and must be purchased.
The following is the file format used by Controlled Automation for its Cad Conversion system when the CADCONV field in the setup is set to 'S'. This file is in ASCII format. Fields are delimited by a space, or newline. Blanks in a field are represented by an underscore. All distance fields are in decimal inches and are 8 chars including the decimal point. Weight field is in decimal pounds and is 8 chars including the decimal point. Only one decimal place is excepted in the Weight field.
Jobid - 10 char max.
Group - 10 char max.
Mark - 10 char max.
Length - distance field
desctp - (EG. W for beams L for angles 2 char max)
Web depth - distance field - (should be the same as in AISC description e.g. 10 for a W 10X45 beam and 4.0 for an L 4" X 3"1/2 X 1/4 angle).
Weight per foot or Short Leg lengthXthickness on Angles - weight or distance X distance field (should be the same as in AISC description e.g. "45" for the weight of a W 10X45 beam, "3.5X0.25" for an L 4" X 3"1/2 X 1/4 angle).
Quantity - 3 chars
Web tool size1 - distance field (SEE BELOW)
Web tool size2 - distance field
Web tool Shape - 2 char max
Top flange near tool size1 - distance field (Top Flange near is the short leg on angle)
Top flange near tool size2 - distance field
Top flange near tool Shape - 2 char max
Top flange far tool size1 - distance field
Top flange far tool size2 - distance field
Top flange far tool Shape - 2 char max
Bottom flange near tool size1 - distance field
Bottom flange near tool size2 - distance field
Bottom flange near tool Shape - 2 char max
Bottom flange far tool size1 - distance field
Bottom flange far tool size2 - distance field
Bottom flange far tool Shape - 2 char max
Number of Operations - 3 chars
All operations are measured from the left end of the material.
For each hole and layout operation there are the following fields:
X position - distance field
U position - distance field (this field is the distance between holes split about the web on near/far BEAM flange holes, twice the distance from the center of the web on single BEAM flange holes and the actual gage on anything else)
Unit - 2 char max
For Stencil and Tool change operations the fields are shown with that operation further along in this document.
The units are defined as follows:
NOTE: For units 20,21,and 22 there is an aditional field besides the X position U position and Unit. There is also a character string of up to 24 characters specifying what is to be stencilled on the material.
NOTE: For units 30,31,32,33, and 34 the X Position and U Position fields are defined as follows:
Hole sizes are as follows. - 13/16 X 1" END RADIUS
SIZE1 SIZE2 SHAPE
0.8125 1.0000 ER
LEGAL HOLE SHAPES ARE
Multiple parts can be in the same file.